• 尊龙凯时 - 人生就是搏!

    the bore of uCT 528

    Simple is a new smart

    uCT 528 is designed for sophisticated CT applications through simple operations, coming with lower radiation dose, higher efficiency and improved profitability.

    Boost efficiency of routine practices

    Smart Workflow

    Reduce total cost of ownership

    Smart Design

    Deliver lower radiation dose and better patient care

    Smart Dose

    uCT 528 with Smart Workflow, Smart Design and Smart Dose

    Smart Workflow

    a patient is in the bore for a fast scan
    Easy-Logic

    The system predicts the user's coming operation, based on which the scan procedure is automatically arranged

    Easy-Range

    EasyRange generates the optimized 3D dose distribution based on anatomic information, making each exam customized

    Smart Design

    Advanced post-processing applications of uCT 528
    Advanced Applications

    Advanced post-processing applications* are integrated on the console to improve diagnostic convenience without a separate workstation

    *Advanced post-processing applications are registered separately from CT

    Green Mode


    uECO mode saves 30% power consumption compared to conventional stand-by mode

    Advanced post-processing applications of uCT 528

    Smart Dose

    uDose 3D Dose Modulation

    uDose 3D Dose Modulation

    uDose generates an optimized 3D dose distribution plan for every individual scan according to anatomical information

    KARL 3D Iterative Denoising

    KARL 3D Iterative Denoising

    KARL 3D performs in both projection and image spaces to provide low dose and high quality images

    70kV Scan Mode

    70kV Scan Mode

    70kV scan mode can increase signal-to-noise ratio(SNR), which can be especially beneficial for pediatric patients, contrast imaging and CT venography (CTV) imaging

    Innovation Z-Detector

    Z-Detector with High Quality Material, Ultra-low Noise Design and  Fine Sampling
    High Quality Material

    Gadolinium oxysulfide scintillator (GOS) provides a fast and high conversion efficiency of X-rays.

    Ultra-low Noise Design

    The Z-Detector with highly integrated technology, significantly reduces noise to provide low dose, high quality images.

    Fine Sampling

    The refined voxel size realizes the exquisite visualization of anatomical details.

    Clinical Applications
    Head and Neck CTA

    Head and Neck CTA

    Lung Density Analysis

    Lung Density Analysis

    Review 3D - Hip Joint

    Review 3D - Shoulder Joint

    Review 3D - Hip Joint

    Review 3D - Hip Joint

    Large Range Scan-Abdominal CTA

    Large Range Scan - Abdominal CTA

    CTU

    CTU

    友情链接: