    An Entirely New Species

    The uMR® Jupiter represents a real breakthrough in the evolution of MRI, in which the brand-new 5.0T superconducting magnet as well as RF system is designed using state-of-the-art technology and custom sequences are developed to achieve entirely new levels of innovation. It will allow you explore new frontiers in ultra-high field (UHF) MRI by enabling exclusive whole-body 5.0T clinical and research applications. A new species of whole-body MRI says hello to the world.

    Unprecedented Ultra-definition Imaging

    Revolution Made Real

    All-in-one Solution for Clinical and Translational Research

    Revolution Made Seamless

    Raise the Field Strength without Raising the Fringe Field

    Revolution Made Accessible

    Unprecedented Ultra-definition Imaging of Jupiter 5.0T

    uAIFI Inside

    Empowered by the uAIFI Technology Platform, the potential for uMR® Jupiter is even more anticipated with significant performance enhancements, more powerful imaging capabilities, better workflow, and improved user experience.

    uAIFI inside the uMR® Jupiter 5

    Unique 8ch Volume Transmit Coil

    The 8-channel independently controlled RF transmission architecture allows for dynamic real-time B1 field calibration for different patients, including the amplitude, phase, and waveform of the RF pulse. It effectively solves the problem of UHF B1 inhomogeneity to achieve uniform excitation of the human body, bringing whole-body UHF MR imaging into a clinical setting for the first time.

    the 8-channel independently controlled RF transmission architecture inside uMR® Jupiter 5.0T

    World's First Whole-body UHF MR Imaging

    In the field of UHF MRI, there has been a great deal of attention paid to achieve perfect compatibility between clinical diagnosis and research exploration. To make a difference, the uMR® Jupiter addresses the three major challenges facing UHF MRI: RF B1 field inhomogeneity, RF safety, and high siting requirement. It will lead to a new era in UHF imaging that will facilitate precise diagnosis and mechanism studies of whole-body diseases, including those of the heart, abdomen, pelvis, and many others.

    Whole-body UHF MR Imaging by uMR® Jupiter 5.0T

    Ultra-high Performance Gradients

    3.5 MW Peak Power Amplifier of UIH

    3.5 MW Peak Power

    Whole-body UHF MRI gradient performance is now improved to an entirely new level thanks to our state-of-the-art gradient power amplifier which was developed in-house by United Imaging.

    diffusion-weighted imaging for the brain

    120 mT/m & 200 T/m/s

    Significantly increase power of diffusion-weighted imaging and functional MRI with outstanding accuracy and stability for the brain research.

    5.0T high-resolution DTI  showing U-fibers

    High-resolution DTI

    5.0T high-resolution DTI clearly shows U-fibers that are not visible on conventional 3.0T.

    5.0T high-resolution BOLD

    Accurate BOLD

    5.0T high-resolution BOLD more accurately shows the distribution of activated areas on the deep cortex.

    Groundbreaking 5.0T Magnet Technology

    0.015 ppm @20 DSV Homogeneity and 1.3 ppm @50 DSV Homogeneity powered by 5.0T Magnet Technology

    Remarkable Homogeneity

    Facilitate whole-body clinical and research applications.
    0.015 ppm @20 DSV Homogeneity (Guaranteed).
    1.3 ppm @50 DSV Homogeneity (Guaranteed).

    UHF MRI with Lowing Sitting Requirement

    Low Siting Requirement

    The system installation requirements are comparable to those of a conventional 3.0T MRI thanks to its innovative magnet architecture with optimized active shielding design, which makes UHF MRI deployment easier than ever.

    Advance Your Clinical Dimensions

    TOF MRA 3.0T vs. 5.0T with the same scan parameters

    TOF MRA

    3.0T vs. 5.0T with the same scan parameters.

    SWI: 3.0T vs. 5.0T with the same scan parameters.

    SWI

    3.0T vs. 5.0T with the same scan parameters.

    Hippocampus 3.0T vs. 5.0T with the same scan parameters

    Hippocampus

    3.0T vs. 5.0T with the same scan parameters.

    Kidney 3.0T vs. 5.0T with the same scan parameters

    Kidney

    3.0T vs. 5.0T with the same scan parameters.

    Prostate CSI 3D 3.0T vs. 5.0T with the same scan parameters

    Prostate CSI 3D

    3.0T vs. 5.0T with the same scan parameters.

    Clinical Application

    • Neurology
    • Abdominal Imaging
    • Cardiac Imaging
    • Orthopedics
    T1W GRE FSP 3D Voxel Size: 0.7x0.7x0.7 mm3

    T1W GRE FSP 3D

    Voxel Size: 0.7×0.7×0.7 mm3

    T2W FLAIR MATRIX 3D Voxel Size: 0.5×0.5×0.5 mm3

    T2W FLAIR MATRIX 3D

    Voxel Size: 0.5×0.5×0.5 mm3

    T2W FSE TRA/COR Voxel Size:0.25x0.25x2 mm3

    T2W FSE TRA/COR

    Voxel Size: 0.25×0.25×2 mm3

    ASL 3D

    Voxel Size: 0.7×0.7×0.7 mm3

    DTI Voxel Size: 1x1x1 mm3

    DTI

    Voxel Size: 1×1×1 mm3

    Pancreas T2W FSE FS TRA MicroView

    Pancreas T2W FSE FS TRA MicroView

    Prostate T2W FSE FS TRA

    Prostate T2W FSE FS TRA

    Cardiac Imaging

    Cardiac Imaging

    Knee T1W FSE SAG

    Knee T1W FSE SAG

    Knee PDW FSE FS SAG

    Knee PDW FSE FS SAG

    Shoulder PDW FSE FS COR

    Shoulder PDW FSE FS COR

    Ankle PDW FSE FS SAG

    Ankle PDW FSE FS SAG

    L-spine T1W FSE SAG

    L-spine T1W FSE SAG

    L-spine T2W FSE SAG FS

    L-spine T2W FSE SAG FS

    L-spine T2W FSE SAG

    L-spine T2W FSE SAG

    L-spine T2W FSE TRA

    L-spine T2W FSE TRA

    Whole-spine lmaging

    Whole-spine Imaging